48T
$299.00
96T
$399.00
Species:
Mouse
Alternative Name:
CD30 antigen, CD30, CD30KI-1, CD30L receptor, cytokine receptor CD30, D1S166EKi-1, Ki-1 antigen, Lymphocyte activation antigen CD30, TNFRSF8, tumor necrosis factor receptor superfamily member 8, tumor necrosis factor receptor superfamily, member 8
Uniport ID:
Q60846
Assay Type:
Sandwich
unit:
pg/mL
Standard:
3000pg/mL
Sensitivity:
28.13 pg/mL
Detection Range:
46.88-3000pg/mL
Assay Time:
3.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=100μL
Research:
Reproductive science;
Test Principle:
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Mouse CD30. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse CD30 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse CD30, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Mouse CD30.You can calculate the concentration of Mouse CD30 in the samples by comparing the OD of the samples to the standard curve.
| pg/mL | OD | Corrected |
|---|---|---|
| 3000 | 2.385 | 2.338 |
| 1500 | 1.599 | 1.552 |
| 750 | 0.894 | 0.847 |
| 375 | 0.394 | 0.347 |
| 187.5 | 0.239 | 0.192 |
| 93.75 | 0.13 | 0.083 |
| 46.88 | 0.093 | 0.046 |
| 0 | 0.047 | 0 |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
| Intra-assay Precision | Inter-assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 20 | 20 | 20 |
| Mean(ng/mL) | 89.48 | 677.82 | 1112.92 | 55.24 | 723.88 | 1383.65 |
| Standard deviation | 2.94 | 22.16 | 52.57 | 3.28 | 35.82 | 71.37 |
| C V (%) | 3.49 | 4.36 | 4.7 | 4.63 | 4.87 | 3.27 |
| Sample Type | Range(%) | Average Recovery(%) |
|---|---|---|
| Serum (n=8) | 83-97 | 90 |
| EDTA plasma (n=8) | 80-97 | 87 |
| Cell culture media (n=8) | 88-103 | 95 |
| Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
|---|---|---|---|---|
| 1:2 | Range (%) | 85-95 | 85-96 | 80-92 |
| Average (%) | 87 | 85 | 81 | |
| 1:4 | Range (%) | 82-91 | 85-96 | 87-103 |
| Average (%) | 86 | 90 | 90 | |
| 1:8 | Range (%) | 86-93 | 87-101 | 89-98 |
| Average (%) | 91 | 95 | 98 | |
| 1:16 | Range (%) | 81-94 | 85-102 | 81-95 |
| Average (%) | 88 | 86 | 84 |